Flow Cytometer Cell Analyzer

SPECIFICATION

Model: BD FACSCalibur

Manufacturer: BD Biosciences

DESCRIPTION

The BD FACSCaliburTM platform allows users to perform both cell analysis and cell sorting in a single benchtop system. The system supports a variety of research and clinical applications and is complemented by a broad suite of intuitive software solutions to streamline analysis for a wide range of applications including enumeration of lymphocyte subsets, stem cells, residual white blood cells and reticulocytes.

Function and Capabilities
  • Optical path configuration
  • Dual-laser design for multicolour analysis
  • Data management
  • A comprehensive quality assurance system
  • Unique easy-to-use sorting technology
Technical Specifications
PropertiesBD FACSCalibur
Noise level
<60dBA (Idle Mode)
<75dBA (Run Mode)
Sampling mode
High-throughput (HT)
Standard (STD)
Sampling volume
2-10uL in HT mode
2-200uL in STD mode
Cleaning cyclesAutomated daily and monthly cleaning protocols

CONTACT

Person in charge: Ragavan A/L Murugiah

Lab location: 4-7-11

Email address: murugiah.ragavan@monash.edu

Contact number: 603-55146343

SPECIFICATION

Model: AMNIS Image Stream MK II

Manufacturer: EMD Milipore Merck

DESCRIPTION

The Image Stream MK II is a benchtop, multispectral, imaging flow cytometer designed for the acquisition of up to 12 channels of cellular imagery. By collecting large numbers of digital images per sample and providing a numerical representation of image-based features, the  Image Stream MK II combines the per cell information content provided by standard microscopy with the statistical significance afforded by large sample sizes common to standard flow cytometry. With the Image Stream MK II System, fluorescence intensity measurements are acquired as with a conventional flow cytometer; however, the best applications for the Image Stream MK II take advantage of the system's imaging abilities to locate and quantitate the distribution of signals in or between cells.

Function and Capabilities
  • Multichannel immunophenotyping
  • Exceptional fluorescence sensitivity
  • Part white blood cell differential
  • Instant population viewer
  • Image gallery
  • Instrument status at a glance
  • Gating without guesswork
  • Efficient sample handling
Technical Specifications
PropertiesAMNIS Image Stream MK II
High-throughputAnalyses thousands of cells per second at up to 60X magnification
IntuitiveSimple user interface with real time plotting and gating
AdaptableCan be configured with 1 to 7 lasers
BoundlessVariable magnification images small particles and your largest cells
Familiar Dot Plots and Histograms
Data plots are updated in real time, just as with conventional flow cytometers. Morphologic parameters such as Area, Cell Width, Cell Height, Aspect Ratio, and others can be plotted on the spot.

CONTACT

Person in charge: Ragavan A/L Murugiah

Lab location: 4-7-11

Email address: murugiah.ragavan@monash.edu

Contact number: +603-55146343